Skip to content

mmWave and Thermal: Three Projects

mmWave and Thermal: Three Projects

Chapter 25 Sections 10 and 12 covered proximity/presence and physiological sensing selection; this section turns three “invisible needs” into hands-on projects: room-level person tracking (mmWave radar), sleep monitoring (radar/mattress sensing), and breathing and heart-rate extraction (60 GHz radar micro-motion). The hard part is not wiring but separating “the person” from clutter in the signal. By the end you will be able to:

  • Use a mmWave radar (e.g. a 60 GHz C1001-class module) for staged presence/breathing/heart projects
  • Follow the processing chain from raw returns to “present, breathing rate, heart rate”
  • Design a three-tier progression: presence → breathing trend → heart-rate estimate
  • Recognise false-positive sources (multipath, pets, body movement) and their countermeasures
  • Completed Chapter 25 Section 10 (proximity/presence) and Section 12 (physiological)
  • A mmWave radar module (e.g. DFRobot C1001, 60 GHz) connected to ESP32 (UART/I²C)
  • A way to observe raw data over serial/plots

The three projects’ signal chain (easy to hard)

Section titled “The three projects’ signal chain (easy to hard)”
Project Input Processing Output Difficulty
Room presence/tracking distance/angle/micro-motion raw threshold plus debounce plus zones present/absent, coarse position Low
Sleep monitoring body movement plus breathing micro-motion band filtering plus period stats turns, breathing trend, in-bed Medium
Breathing/heart extraction phase/distance series of chest micro-motion band-pass plus FFT/peak detect breathing rate, heart-rate estimate High

Shared core: physiological measurement is separating periodic micro-motion from noise and body movement — filter first (breathing ~0.1–0.5 Hz, heart ~0.8–2 Hz), then estimate frequency.

  1. Presence: use the radar’s present/absent decision first, validate mounting height/orientation/coverage — most useful and easiest to succeed
  2. Breathing trend: read micro-motion, band-pass to breathing, check for a stable period — give a trend, not an absolute value
  3. Heart extraction: noisy and movement-sensitive; needs still conditions plus a data window plus a quality/confidence metric — treat as an estimate
  1. Multipath/wall penetration: the radar may “see through” walls; set range gates and limit field of view
  2. Pets/fans/curtains: confuse micro-motion sources; combine amplitude/range/direction with time correlation
  3. Movement swamps physiology: when movement is large, heart/breathing is untrustworthy; output a signal-quality flag
  4. Absolute accuracy: consumer radar heart rate is a trend/estimate, not a medical reading

[Needs board/measurement] The register/output format of a specific radar module, and measured accuracy and usable range for breathing/heart extraction, must be calibrated on the chosen module; the frequency bands and flow here are the general method.

Check Expected result Verified
Presence detection stable Reliable present/absent in coverage, debounce works
Breathing band-pass works Stable breathing cycle visible at rest
Heart estimate has quality Output carries confidence, degrades under movement
False-positive controls Pet/fan scenarios have mitigations and records
Mounting calibrated Height/orientation/range gate set

Issue 1: reports presence when nobody is there

Section titled “Issue 1: reports presence when nobody is there”

Cause: multipath, far-field micro-motion, threshold too low.

Action: tighten range gate, raise amplitude threshold, use time-correlation debounce (the Chapter 25 debounce idea).

Cause: movement contamination plus too-short window plus no quality filter.

Action: output only in still windows, lengthen the data window, drop or flag when the quality score is low.

  • Do: start from presence and climb to breathing then heart; never start with heart rate
  • Do: label every physiological reading as trend/estimate with a quality flag
  • Do: calibrate the mounting geometry before tuning algorithms
  • Don’t: treat a consumer radar heart rate as a medical device
  • Don’t: use a single threshold for presence, ignoring multipath and interferers

Key points of this section:

  1. The three projects are one easy-to-hard chain: presence → breathing trend → heart estimate
  2. Physiology = separating periodic micro-motion from noise/movement: band-pass then estimate
  3. False positives are the main battlefield: multipath, pets, movement — met with joint criteria and quality flags
  4. Stage the build, calibrate first, flag quality; never impersonate medical accuracy

Building a commercial IoT product?

We provide ESP32 ODM design-to-manufacturing services. From prototype to production — the team behind this tutorial can build it with you.

💡 Mention tutorial.imagrove.com in your Alibaba chat with us — get 10% off your custom project quote.

Talk to us →

First published attutorial.imagrove.com/project-factory-environment/15-mmwave-and-thermal-three-projects/Please credit Imagrove and link back to this page when quoting or republishing.

Questions or issues with this tutorial?

Sign in with GitHub to leave a comment. If a step fails for you, tell us — we verify it and update the tutorial.